
Waterproofing Membrane
SBS Modified Bituminous Waterproofing Membrane
EL-N100
EL-N100 waterproofing membrane is manufactured by special customized premium asphalts, with Styrene Butadiene Styrene (SBS), elastomer resin as its modifier and reinforced by polyester base cloth. The structure of it consist of polymer modified bitumen materials, middle reinforcement cloth and some surface cover materials. PRODUCT FEATURES1. High elongation ability, stable and good adaptability to concrete transform or crack.2. Excellent ability of high and low temperature resistance, especially suitable for cold area.3. Great ability of puncture resistant, tear resistant and abrasive resistant.4. Easy to construct, can be constructed anytime by fire torch, very reliable. SCOPE OF APPLICATION1. Industrial and civil roofing construction, such as insulation roofs, planted roofs, roof parking lots and inverted roofs, etc.2. Industrial and civil underground construction, indoor swimming pools, fire reservoirs, etc.3. Tunnels, subways, concrete bridges, sewage plants and refuse landfills, etc.4. Water conservancy facilities such as pools and water channels, etc. APPLICATION METHOD1. Check and clean the concrete before paving. Use dust collector or blower to help clean the corners if needed.2. Primer Brush: Remember the primer should be brushed evenly on the substrate.3. Detail Processing: After the primer dries, should deal with those sections where need to do extra waterproof layer according to the relevant specification and requirement.4. Pave the membrane from middle to both ends of the concrete. Pave on the wall should fix the end at the bottom first, and then roll the membrane from low to high by fire torch method. Spray gun should keep the distance of 30cm to the membranes while heating. Rolling and pressing the membranes with tools while heating, make sure the membrane completely stick to the concrete.5. The width of connecting Joint should be over 100mm. Those connecting area must be heating with as well until the bitumen of joints natural dripping. SPECIFICATIONSAccording to different standards, this membrane can be divided into different types.Reinforcements: polyester(PY), glass fiber(G), glass fiber reinforced polyester (PYG)Surface materials: polyethylene film(PE), fine sand(S), the mineral aggregate(M)Physical and mechanical properties: TYPE I and TYPE IIProduct specifications: width:1000mm; thickness: 3mm, 4mm, 5mm NOTES1. Don't construct in Rainy, snowy or high windy(>5 level) days.2. Construction temperature should be above 0℃.3. Protect the membranes from getting wet in rainy days.4. When heating, flame spraying guns should maintain a proper distance with the membranes and should heat them evenly. Overheating should be prevented.5. Safety precautions are necessary and fire equipment should be placed properly. PACKING, TRANSPORTATION AND STORAGE1. Different types or specifications should be separated. Keep them dry and ventilated, out of the sun or rain.2. Storage Temp. Should be within 5~45 Celsius degree,3. Prevent it from inclination or lateral pressure. If necessary, cover it with felt-cloth.4. Storage time: 1 year under normal operation of storage.5. Membranes should be piled upright with only ONE layer.
PET Wet-applied Waterproofing Membrane
EL-W200
EL-W200 waterproofing membrane is a cost-effective and environmental-friendly construction material, which contains premium asphalt adhesive materials and polyester (PET) film. With the advantages of good adhesive strength, excellent bonding power, perfect water impermeability, it can be applied on humid concrete (no visible water) with both self-adhesive and wet-applied methods on the wet base surface. PRODUCT FEATURES1. Perfect adhesive strength, can be easily associated to complicated base surfaces.2. Can use cement as glue with wet apply method, which is safe and environmental protection.3. Self-adhesive and wet-applied methods make the construction safe and environmental friendly.4. Leakage rarely happens even the membrane is broken for its good creep deformation ability5. High cost effective and widespread use.6. The membrane can be used for temporary repairing in the steel roofing structure.7. Wide usage in civil and industrial waterproofing projects like basements and roofs, etc. SCOPE OF APPLICATIONWidespread use for industrial and residential buildings and underground waterproof construction.Suitable for basement concrete, wall, floor and roof waterproof construction. APPLICATION PROCESSES1. Pre-laid Method:Base level processing -> Detail place Processing -> Pre-laid the membrane -> Joints and corners treatment -> Peel off the isolation film -> concreting2. Wet Apply Method:Base level processing -> Mixing cement as glue-> Detail place processing-> Pave the membrane ->Joints and corners treatment -> Sealant processingNOTES1. Cover the membranes with the protection layer after paving.2. No steps on membranes until the membranes sticking tightly to the base surface.3. No heavy and sharp objects on the membranes after paving. PACKING, TRANSPORTATION AND STORAGE1. Membranes should be stored separately. Keep membranes dry and ventilated, protected from sun and rain.2. One layer up-right storage in warehouse, no more than 2 layers up-right during transportation.3. Prevent it from inclination or lateral pressure. If necessary, cover it with felt-cloth.4. Storage period: 1 year under normal operation of storage.
扫描二维码分享到微信